Dehydration as alternative sample preparation for soft X‐ray tomography.

  • Published In: Journal of Microscopy, 2023, v. 291, n. 3. P. 248 1 of 3

  • Database: Academic Search Ultimate 2 of 3

  • Authored By: Chatzimpinou, Anthoula; Funaya, Charlotta; Rogers, David; O'Connor, Stephen; Kapishnikov, Sergey; Sheridan, Paul; Fahy, Kenneth; Weinhardt, Venera 3 of 3

Abstract

Soft X‐ray tomography (SXT) is an imaging technique to visualise whole cells without fixation, staining, and sectioning. For SXT imaging, cells are cryopreserved and imaged at cryogenic conditions. Such 'near‐to‐native' state imaging is in high demand and initiated the development of the laboratory table‐top SXT microscope. As many laboratories do not have access to cryogenic equipment, we asked ourselves whether SXT imaging is feasible on dry specimens. This paper shows how the dehydration of cells can be used as an alternative sample preparation to obtain ultrastructure information. We compare different dehydration processes on mouse embryonic fibroblasts in terms of ultrastructural preservation and shrinkage. Based on this analysis, we chose critical point (CPD) dried cells for SXT imaging. In comparison to cryopreserved and air‐dried cells, CPD dehydrated cells show high structural integrity although with about 3–7 times higher X‐ray absorption for cellular organelles. As the difference in X‐ray absorption values between organelles is preserved, 3D anatomy of CPD‐dried cells can be segmented and analysed, demonstrating the applicability of CPD‐dried sample preparation for SXT imaging. LAY DESCRIPTION: Soft X‐ray tomography (SXT) is an imaging technique that allows to see the internal structures of cells without the need for special treatments like fixation or staining. Typically, SXT imaging involves freezing and imaging cells at very low temperatures. However, since many labs lack the necessary equipment, we explored whether SXT imaging could be done on dry samples instead. We compared different dehydration methods and found that critical point drying (CPD) was the most promising for SXT imaging. CPD‐dried cells showed high structural integrity, although they absorbed more X‐rays than hydrated cells, demonstrating that CPD‐dried sample preparation is a viable alternative for SXT imaging. [ABSTRACT FROM AUTHOR]

Additional Information

  • Source:Journal of Microscopy. 2023/09, Vol. 291, Issue 3, p248
  • Document Type:Article
  • Subject Area:Anatomy and Physiology
  • Publication Date:2023
  • ISSN:0022-2720
  • DOI:10.1111/jmi.13214
  • Accession Number:169828199
  • Copyright Statement:Copyright of Journal of Microscopy is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)