Postprocedure serum amylase or lipase levels predict postendoscopic retrograde cholangiopancreatography pancreatitis: Meta‐analysis of diagnostic test accuracy studies and utility assessment.

  • Published In: Digestive Endoscopy, 2024, v. 36, n. 6. P. 670 1 of 3

  • Database: Academic Search Ultimate 2 of 3

  • Authored By: Hirota, Morihisa; Itoi, Takao; Morizane, Toshio; Koiwai, Akinobu; Yasuda, Ichiro; Ryozawa, Shomei; Mukai, Shuntaro; Ikeura, Tsukasa; Irisawa, Atsushi; Iwasaki, Eisuke; Katanuma, Akio; Kitamura, Katsuya; Takenaka, Mamoru; Ito, Tetsuhide; Masamune, Atsushi; Mayumi, Toshihiko; Takeyama, Yoshifumi 3 of 3

Abstract

Objectives: We aimed to clarify the clinical utility of measuring serum pancreatic enzymes after endoscopic retrograde cholangiopancreatography (ERCP) for the purpose of predicting post‐ERCP pancreatitis (PEP) by a meta‐analysis of diagnostic test accuracy studies. Methods: Studies on the prediction accuracy of PEP by serum amylase or lipase measured at 2, 3, and 4 h after ERCP were collected. A literature search was performed in PubMed and the Cochrane Library database for studies published between January 1980 and March 2023. The quality of individual studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies‐2. Data were analyzed using Meta‐DiSc 2.0 software. Results: We searched the databases and identified 20 observational studies (12,313 participants). PEPs were defined according to criteria by Cotton or modified Cotton, revised Atlanta criteria, or the Japanese criteria. Meta‐analysis of eight studies (4389 participants) showed a pooled sensitivity of 71.1% (95% confidence interval [CI] 56.1–82.5) and pooled specificity of 91.2% (95% CI 85.9–94.6) for the serum amylase cut‐off value at 3 times the upper limit of normal (ULN). Another meta‐analysis of five studies (1970 participants) showed a pooled sensitivity of 85.8% (95% CI 61.9–95.7) and pooled specificity of 85.3% (95% CI 81.9–88.1) for the serum lipase cut‐off value at 3 times ULN. Conclusion: Despite a high risk of bias due to various reference standards, this updated meta‐analysis and the utility assessment by a decision tree showed the utility of serum amylase or lipase levels more than 3 times ULN measured 2–4 h after ERCP for predicting PEP. [ABSTRACT FROM AUTHOR]

Additional Information

  • Source:Digestive Endoscopy. 2024/06, Vol. 36, Issue 6, p670
  • Document Type:Article
  • Subject Area:Biology
  • Publication Date:2024
  • ISSN:0915-5635
  • DOI:10.1111/den.14718
  • Accession Number:177929454
  • Copyright Statement:Copyright of Digestive Endoscopy is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Looking to go deeper into this topic? Look for more articles on EBSCOhost.