JOURNAL ARTICLE

Comparison between Endobronchial Ultrasound-Guided Transbronchial Node Biopsy and Transbronchial Needle Aspiration: A Meta-Analysis.

  • Published In: Respiration, 2024, v. 103, n. 12. P. 752 1 of 3

  • Database: Academic Search Ultimate 2 of 3

  • Authored By: Yang, Wuchen; Yang, Huizhen; Zhang, Quncheng; Herth, Felix J.F.; Zhang, Xiaoju 3 of 3

Abstract

Introduction: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) can be limited by the inadequacy of intact tissues, especially in patients with lymphoma, sarcoidosis, and lymph node tuberculosis. A novel technique called transbronchial node biopsy (TBNB) by forceps or cryoprobe has been proposed and studied to improve specimen quality and diagnostic yield. We performed a systematic review of studies describing the safety and sensitivity of EBUS-TBNB versus EBUS-TBNA in diagnosing intrathoracic lymphadenopathy/masses. Methods: We systematically searched MEDLINE, Embase, Cochrane, and China National Knowledge Infrastructure to identify studies focusing on the application of EBUS-TBNB for diagnosis of intrathoracic lymphadenopathy. The quality of each study was evaluated using the QUADAS-2 tool. Using inverse-variance (I-V) weighting, we performed a meta-analysis of diagnostic yield estimations. We also reviewed the complications related to the procedure. Results: Thirteen studies were included in the final analysis. The meta-analysis yielded a pooled overall diagnostic yield of 77.80% (939/1,207) for EBUS-TBNA and 86.01% (834/958) for EBUS-TBNB, with an inverse-variance-weighted odds ratio of 3.13 (95% confidence interval [CI], 1.61–6.01; p = 0.0008) and I2 of 82%. The pooled diagnostic yield of EBUS-TBNB versus EBUS-TBNA for the diagnosis of malignancy (including primary lung cancer and extrapulmonary malignancy) was 84.53% (590/698) for EBUS-TBNA and 90.84% (476/524) for EBUS-TBNB, with an I-V-weighted OR of 2.33 (95% CI, 1.15–4.74; p = 0.02) and I2 of 64%. The pooled diagnostic yield of EBUS-TBNB versus EBUS-TBNA for the diagnosis of benignancy was 71.19% (252/354) for EBUS-TBNA and 86.62% (233/269) for EBUS-TBNB, with an I-V-weighted OR of 4.39 (95% CI, 2.00–9.65; p = 0.002) and I2 of 59%. The overall complications included bleeding (n = 11, 0.90%), pneumomediastinum (n = 6, 0.49%), pneumothorax (n = 6, 0.49%), pneumonia (n = 4, 0.33%), respiratory failure (n = 1, 0.08%), and haemoptysis (n = 1, 0.08%). The funnel plot analysis illustrated no major publication bias. Conclusions: EBUS-TBNB improves the overall diagnostic yield of sampling intrathoracic lymphadenopathy and mass lesions relative to EBUS-TBNA. The complication rate of EBUS-TBNB is higher than that of EBUS-TBNA but reportedly lower than that of surgical biopsies. [ABSTRACT FROM AUTHOR]

Additional Information

  • Source:Respiration. 2024/12, Vol. 103, Issue 12, p752
  • Document Type:Article
  • Subject Area:Consumer Health
  • Publication Date:2024
  • ISSN:0025-7931
  • DOI:10.1159/000540859
  • Accession Number:181625901
  • Copyright Statement:Copyright of Respiration is the property of Karger AG and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Looking to go deeper into this topic? Look for more articles on EBSCOhost.