Surface Modification of NiTi Alloy with Sputtered Tantalum Coatings to Improve its Hardness, Corrosion Resistance and Biocompatibility.

  • Published In: International Journal of Nanoscience, 2024, v. 23, n. 3. P. 1 1 of 3

  • Database: Academic Search Ultimate 2 of 3

  • Authored By: Khathim, Sena'a E.; Al-Rawi, Bilal K.; Khalaf, Mohammed K. 3 of 3

Abstract

In this research, titanium alloys including smart nitinol (NiTi) were studied. The (NiTi) alloy tends to emitting (Ni) toxic ions due to its low resistance to corrosion within the body conditions over time. For (NiTi) coating process, the magnetron plasma sputtering (DC) technique was used with Aragon gas ratio of (90%) and Oxygen of (10%) in order to coat the alloy with Tantalum and its Oxide (Ta2O 5) thin films. This is one of the methods used to improve the biocompatibility and better adhesion stability of the membrane on the (NiTi) surface, since Tantalum and its oxides are biocompatible and are not affected by the body fluids. Hardness, corrosion and biocompatibility were tested. The results showed improvement in the nominated properties using this coating technique. The hardness for the non-coated sample was (630 Kgf/mm 2) , meanwhile, the coated sample recorded (762 Kgf/mm 2) using sputtering power of (25 W) with a thickness of (226 nm). Tantalum and its precipitated oxides on a pillar of thickness (90.4–226 nm) also exhibited a biocorrosion enhancement, when it was immersed in a Simulated Body Fluid (SBF). The corrosion rate for the non-coated sample was (1.204 × 10 − 2) , meanwhile for the coated sample, its value was (3.453 × 10 − 5) at sputtering power of (15 W), considered as the lower corrosion rate. The scanning electron micrographs also showed an increase in the biocompatibility for the coated nitinol alloys (NiTi) in comparison with the non-coated, ones since it showed a clear formation of Hydroxyapatite (HA) on the sample surface after immersion in the SBF. This behavior was confirmed by the XRD measurements, which presented higher HA peaks on the coated samples surface in comparison with the non-coated samples. [ABSTRACT FROM AUTHOR]

Additional Information

  • Source:International Journal of Nanoscience. 2024/06, Vol. 23, Issue 3, p1
  • Document Type:Article
  • Subject Area:Geology
  • Publication Date:2024
  • ISSN:0219-581X
  • DOI:10.1142/S0219581X23500734
  • Accession Number:176925946
  • Copyright Statement:Copyright of International Journal of Nanoscience is the property of World Scientific Publishing Company and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Looking to go deeper into this topic? Look for more articles on EBSCOhost.