JOURNAL ARTICLE

Leadless Pacemaker Implantation Following Lead Extraction in a Patient With Recent Percutaneous Tricuspid Valve Repair.

  • Published In: Pacing & Clinical Electrophysiology, 2025, v. 48, n. 3. P. 320 1 of 3

  • Database: Academic Search Ultimate 2 of 3

  • Authored By: Segreti, Luca; Torre, Marco; Parollo, Matteo; Pistelli, Lorenzo; Cori, Andrea Di; Zucchelli, Giulio 3 of 3

Abstract

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72‐year‐old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin‐resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system. A leadless pacemaker was subsequently implanted without complications, despite the recent tricuspid valve repair. This case highlights the efficacy and safety of leadless pacemakers in complex clinical scenarios, especially when traditional transvenous systems are no longer viable due to infections or other complications. The report underscores the importance of personalized management strategies for cardiac device infections, illustrating that leadless pacemakers offer a feasible and safe alternative even in patients with previous valvular interventions. [ABSTRACT FROM AUTHOR]

Additional Information

  • Source:Pacing & Clinical Electrophysiology. 2025/03, Vol. 48, Issue 3, p320
  • Document Type:Article
  • Subject Area:Health and Medicine
  • Publication Date:2025
  • ISSN:0147-8389
  • DOI:10.1111/pace.15150
  • Accession Number:183898099
  • Copyright Statement:Copyright of Pacing & Clinical Electrophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Looking to go deeper into this topic? Look for more articles on EBSCOhost.