JOURNAL ARTICLE

ANTT® standardisation facilitates new efficiencies with a novel partially-sterile Standard-ANTT PIVC Pack.

  • Published In: British Journal of Nursing, 2023, v. 32, n. 7. P. S4 1 of 3

  • Database: Academic Search Ultimate 2 of 3

  • Authored By: Rowley, Stephen; Clare, Simon 3 of 3

Abstract

Introduction: The widespread adoption of the ANTT®Clinical Practice Framework as a single standard for aseptic technique, has highlighted that many clinical procedures do not require a sterile procedure pack to be performed safely and aseptically. This study explores the utilisation of a partially-sterile procedure pack that is specifically tailored to Standard-ANTT. Methods: A prospective project improvement evaluation, using a non-paired sample (pre: n=41; post: n =33) of emergency department staff in an NHS hospital. Staff were evaluated performing peripheral intravenous cannulations (PIVC) using Standard-ANTT and the B. Braun Standard-ANTT peripheral cannulation pack. Findings: Significant improvements were observed in practice following the implementation of the pack and training in Standard-ANTT, including: Key-Part protection significantly improved (pre: n=28, 68.2%; post: n=33, 100%), and reduction in the Key-Site being touched after disinfection (pre: n=17; 41.4%; post n=5; 15.1%). Conclusions: In conjunction with appropriate education and training, this study provides proof of concept that due to the widespread use of the ANTT Clinical Practice Framework as a single standard aseptic technique, procedure packs that are specifically tailored to Standard-ANTT, can help to promote best practice and improve efficiencies. Definitions: Partially-sterile procedure pack - all items required to be sterile remain in their individual blister wrapper. The final assembled pack itself is not then subjected to a further round of sterilisation as it is not needed. Sterile procedure pack - often contains a mixture of non-sterile and sterile items that have been stripped from their individual blister wrapper requiring the sterilisation of the final assembled pack. [ABSTRACT FROM AUTHOR]

Additional Information

  • Source:British Journal of Nursing. 2023/04, Vol. 32, Issue 7, pS4
  • Document Type:Article
  • Subject Area:Health and Medicine
  • Publication Date:2023
  • ISSN:0966-0461
  • DOI:10.12968/bjon.2023.32.7.S4
  • Accession Number:162975682
  • Copyright Statement:Copyright of British Journal of Nursing is the property of Mark Allen Holdings Limited and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Looking to go deeper into this topic? Look for more articles on EBSCOhost.