JOURNAL ARTICLE

Impact of bronchoscopic lung volume reduction with endobronchial valves on dynamic hyperinflation: Results from the PIERCE study.

  • Published In: Respirology, 2023, v. 28, n. 6. P. 525 1 of 3

  • Database: Academic Search Ultimate 2 of 3

  • Authored By: Fumat, Romane; Dupuis, Marion; Mallah, Siham; Heluain, Valentin; Favard, Florent; Simonneau, Yannick; Dusselier, Matthieu; Barthes, Romain; Pontier, Sandrine; Collot, Samia; Plat, Gavin; Egenod, Thomas; Guibert, Nicolas 3 of 3

Abstract

Background and Objective: Dynamic hyperinflation (DH) is a major marker of exertional dyspnoea in severe emphysema. We hypothesized that bronchoscopic lung volume reduction (BLVR) using endobronchial valves (EBVs) decreases DH. Methods: In this prospective bi‐centre study from both Toulouse and Limoges Hospitals, we assessed DH during an incremental cycle ergometry before and 3 months after EBVs treatment. The primary objective was to observe the change in inspiratory capacity (IC) at isotime. Target lobe volume reduction (TLVR) and changes in residual volume (RV), forced expiratory volume in one‐second (FEV1), mMRC, 6 minutes walking distance (6MWD), BODE and other dynamic measures like tele‐expiratory volume (EELV) were also analysed. Results: Thirty‐nine patients were included, of whom thirty‐eight presented DH. IC and EELV at isotime significantly improved (+214 mL, p = 0.004; −713 mL, p ˂ 0.001, respectively). Mean changes were +177 mL for FEV1 (+19%, p < 0.001), −600 mL for RV (p < 0.0001), +33 m for 6MWD (p < 0.0001), respectively. Patients who responded on RV (>430 mL decrease) and FEV1 (>12% gain) had better improvements compared to non‐responders (+368 mL vs. +2 mL; +398 mL vs. −40 mL IC isotime, respectively). On the opposite, in patients who responded on DH (>200 mL IC isotime increase), changes in TLV (−1216 mL vs. −576 mL), FEV1 (+261 mL vs. +101 mL), FVC (+496 mL vs. +128 mL) and RV (−805 mL vs. −418 mL) were greater compared to non‐responders. Conclusions: DH decreases after EBVs treatment, and this improvement is correlated with static changes. Bronchoscopic lung volume reduction using endobronchial valves leads to a decrease in dynamic hyperinflation; and these changes correlate with improvements in static parameters changes (target lobe volume reduction, residual volume, forced expiratory volume in 1 second, forced vital capacity). Dynamic hyperinflation decrease is deeper in most severe patients. See relatedEditorial [ABSTRACT FROM AUTHOR]

Additional Information

  • Source:Respirology. 2023/06, Vol. 28, Issue 6, p525
  • Document Type:Article
  • Subject Area:Health and Medicine
  • Publication Date:2023
  • ISSN:1323-7799
  • DOI:10.1111/resp.14488
  • Accession Number:163743425
  • Copyright Statement:Copyright of Respirology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Looking to go deeper into this topic? Look for more articles on EBSCOhost.