Technical note: Accuracy and precision of T2 and T2* with a gradient‐echo spin‐echo (GESE) sequence for cardiac imaging.

  • Published In: Medical Physics, 2023, v. 50, n. 12. P. 7946 1 of 3

  • Database: Academic Search Ultimate 2 of 3

  • Authored By: Huang, Qi; Mendes, Jason; Adluru, Ganesh; DiBella, Edward 3 of 3

Abstract

Background: The use of a gradient echo spin echo (GESE) method to obtain rapid T2 and T2* estimation in the heart has been proposed. The effect of acquisition parameter settings on T2 and T2* bias and precision have not been investigated in depth. Purpose: To understand factors impacting the quantification of T2 and T2* values with a gradient echo spin echo (GESE) method using echo planar imaging (EPI) readouts in a reduced field of view acquisition. Methods: The GESE method is implemented with a reduced field‐of‐view using an outer volume suppression (OVS) technique to minimize the time for multi‐echo EPI readouts. The number of EPI readouts (images) for the GESE is optimized using Cramer‐Rao Lower Bound (CRLB) and Monte Carlo simulations with a nonlinear least‐square (NLLS) estimator. The SNR requirements were studied using the latter simulation method for a selected range of T2 and T2* values and T2/T2* ratios. Two healthy control subjects were imaged with the proposed GESE sequence and evaluated with the NLLS estimation method. In addition, the proposed OVS method was compared with a saturation bands OVS method in one subject. Clinical T2 and T2* mappings were used as the reference. Results: The optimal number of EPI readouts is five and the performance is slightly better when the refocusing pulse is placed between the 2nd and 3rd readouts. The SNR requirement for achieving a target bias < 1 ms and standard deviation (SD) < 5 ms is more demanding when T2/T2* ratio increases. The minimum SNR requirement in the GESE acquisition should vary from 6 to 20 depending on specific myocardial T2 and T2* values at 3T. The T2 and T2* estimates using the proposed OVS method and the saturation bands OVS method are both similar to the reference. Conclusion: The GESE sequence with five EPI readouts is a feasible and efficient technique that can estimate T2 and T2* values in the septal myocardium within a heartbeat when the SNR requirement can be satisfied. [ABSTRACT FROM AUTHOR]

Additional Information

  • Source:Medical Physics. 2023/12, Vol. 50, Issue 12, p7946
  • Document Type:Article
  • Subject Area:Physics
  • Publication Date:2023
  • ISSN:0094-2405
  • DOI:10.1002/mp.16569
  • Accession Number:174011323
  • Copyright Statement:Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Looking to go deeper into this topic? Look for more articles on EBSCOhost.