An analytical approach for on‐site analysis of breath samples for Δ9‐tetrahydrocannabinol (THC).
Published In: Journal of Mass Spectrometry, 2024, v. 59, n. 1. P. 1 1 of 3
Database: Academic Search Ultimate 2 of 3
Authored By: Henion, Jack; Hao, Changtong; Eikel, Daniel; Beck, Olof; Stambeck, Peter 3 of 3
Abstract
Increased acceptance of cannabis containing the psychoactive component, Δ9‐tetrahydrocannabinol (THC), raises concerns about the potential for impaired drivers and increased highway accidents. In contrast to the "breathalyzer" test, which is generally accepted for determining the alcohol level in a driver, there is no currently accepted roadside test for THC in a motorist. There is a need for an easily collectible biological sample from a potentially impaired driver coupled with an accurate on‐site test to measure the presence and quantity of THC in a driver. A novel breath collection device is described, which includes three separate sample collectors for collecting identical A, B, and C breath samples from a subject. A simple one‐step ethanol extraction of the "A" breath collector sample can be analyzed by UHPLC/selected ion monitoring (SIM) liquid chromatography/mass spectrometry (LC/MS) to provide qualitative and quantitative determination of THC in breath sample in less than 4 min for samples collected up to 6 h after smoking a cannabis cigarette. SIM LC/MS bioanalyses employed d3‐THC as the stable isotope internal standard fortified in negative control breath samples for quantitation including replicates of six calibrator standards and three quality control (QC) samples. Subsequent confirmation of the same breath sample in the B collectors was then confirmed by a reference lab by LC/MS/MS analysis. Fit‐for‐purpose bioanalytical validation consistent with pharmaceutical regulated bioanalyses produced pharmacokinetic (PK) curves for the two volunteer cannabis smokers. These results produced PK curves, which showed a rapid increase of THC in the breath of the subjects in the first hour followed by reduced THC levels in the later time points. A simpler single‐point calibration curve procedure with calibrators and QC prepared in ethanol provided similar results. Limitations to this approach include the higher cost and operator skill sets for the instrumentation employed and the inability to actually determine driver impairment. [ABSTRACT FROM AUTHOR]
Additional Information
- Source:Journal of Mass Spectrometry. 2024/01, Vol. 59, Issue 1, p1
- Document Type:Article
- Subject Area:Science
- Publication Date:2024
- ISSN:1076-5174
- DOI:10.1002/jms.4987
- Accession Number:174934136
- Copyright Statement:Copyright of Journal of Mass Spectrometry is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Looking to go deeper into this topic? Look for more articles on EBSCOhost.