JOURNAL ARTICLE

Methods to expose subsurface objects of interest identified from 3D imaging: The intermediate sample preparation stage in the correlative microscopy workflow.

  • Published In: Journal of Microscopy, 2023, v. 289, n. 2. P. 107 1 of 3

  • Database: Academic Search Ultimate 2 of 3

  • Authored By: Mitchell, R. L.; Dunlop, T.; Volkenandt, T.; Russell, J.; Davies, P.; Spooner, S.; Pleydell‐Pearce, C.; Johnston, R. 3 of 3

Abstract

The correlative imaging workflow is a method of combining information and data across modes (e.g. SEM, X‐ray CT, FIB‐SEM), scales (cm to nm) and dimensions (2D–3D–4D), providing a more holistic interpretation of the research question. Often, subsurface objects of interest (e.g. inclusions, pores, cracks, defects in multilayered samples) are identified from initial exploratory nondestructive 3D tomographic imaging (e.g. X‐ray CT, XRM), and those objects need to be studied using additional techniques to obtain, for example, 2D chemical or crystallographic data. Consequently, an intermediate sample preparation step needs to be completed, where a targeted amount of sample surface material is removed, exposing and revealing the object of interest. At present, there is not one singular technique for removing varied thicknesses at high resolution and on a range of scales from cm to nm. Here, we review the manual and automated options currently available for targeted sample material removal, with a focus on those methods which are readily accessible in most laboratories. We summarise the approaches for manual grinding and polishing, automated grinding and polishing, microtome/ultramicrotome, and broad‐beam ion milling (BBIM), with further review of other more specialist techniques including serial block face electron microscopy (SBF‐SEM), and ion milling and laser approaches such as FIB‐SEM, Xe plasma FIB‐SEM, and femtosecond laser/LaserFIB. We also address factors which may influence the decision on a particular technique, including the composition, shape and size of the samples, sample mounting limitations, the amount of surface material to be removed, the accuracy and/or resolution of peripheral parts, the accuracy and/or resolution of the technique/instrumentation, and other more general factors such as accessibility to instrumentation, costs, and the time taken for experimentation. It is hoped that this study will provide researchers with a range of options for removal of specific amounts of sample surface material to reach subsurface objects of interest in both correlative and non‐correlative workflows. [ABSTRACT FROM AUTHOR]

Additional Information

  • Source:Journal of Microscopy. 2023/02, Vol. 289, Issue 2, p107
  • Document Type:Article
  • Subject Area:Science
  • Publication Date:2023
  • ISSN:0022-2720
  • DOI:10.1111/jmi.13159
  • Accession Number:161311368
  • Copyright Statement:Copyright of Journal of Microscopy is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Looking to go deeper into this topic? Look for more articles on EBSCOhost.